{"id":25976,"date":"2017-05-16T15:14:22","date_gmt":"2017-05-16T13:14:22","guid":{"rendered":"https:\/\/www.gestlabs.it\/?page_id=25976"},"modified":"2021-08-05T12:54:13","modified_gmt":"2021-08-05T10:54:13","slug":"environmental-testing-temperature-humidity","status":"publish","type":"page","link":"https:\/\/www.gestlabs.it\/en\/environmental-testing-temperature-humidity\/","title":{"rendered":"ENVIRONMENTAL AND RELIABILITY TEST"},"content":{"rendered":"<p>[vc_row full_width=&#8221;stretch_row&#8221; bg_type=&#8221;image&#8221; parallax_style=&#8221;vcpb-vz-jquery&#8221; bg_image_new=&#8221;24939&#8243; bg_image_repeat=&#8221;no-repeat&#8221; parallax_sense=&#8221;40&#8243; disable_on_mobile_img_parallax=&#8221;off&#8221; parallax_content=&#8221;off&#8221; fadeout_row=&#8221;off&#8221; enable_overlay=&#8221;enable_overlay_value&#8221; overlay_color=&#8221;rgba(0,0,0,0.34)&#8221; css=&#8221;.vc_custom_1499264580063{margin-bottom: 0px !important;padding-top: 240px !important;padding-bottom: 160px !important;}&#8221;][vc_column]<h1 class=\"boc_heading  center  boc_animate_when_almost_visible boc_fade-in\"  style=\"margin-bottom: 12px;margin-top: 0px;color: #ffffff;\"><span>ENVIRONMENTAL AND <strong style=\"color: #0ce708;\">RELIABILITY TEST<\/strong><\/span><\/h1><div class=\"boc_divider_holder\"><div class=\"boc_divider  \"  style=\"margin-top: 16px;margin-bottom: 20px;width: 100px;margin-left: auto; margin-right: auto;height: 1px;background: rgba(255,255,255,0.15);\"><\/div><\/div><h3 class=\"boc_heading  center  boc_subheading boc_animate_when_almost_visible boc_fade-in\"  style=\"margin-bottom: 20px;margin-top: 0px;color: #ffffff;\"><span>Discover more about the services<\/span><\/h3>[\/vc_column][\/vc_row][vc_row css=&#8221;.vc_custom_1489507990446{padding-top: 10% !important;}&#8221;][vc_column width=&#8221;1\/2&#8243;]<h2 class=\"boc_heading  al_left  \"  style=\"margin-bottom: 20px;margin-top: 0px;color: #333333;\"><span>ENVIRONMENTAL AND <strong>RELIABILITY TEST<\/strong><\/span><\/h2><h4 class=\"boc_heading  al_left  \"  style=\"margin-bottom: 20px;margin-top: 0px;color: #333333;\"><span>Among the main tests we can perform in our laboratories to evaluate and validate new processes and technologies, there are:<\/span><\/h4><div class=\"boc_divider_holder\"><div class=\"boc_divider  \"  style=\"margin-top: 20px;margin-bottom: 50px;width: 40px;height: 1px;background: #eeeeee;\"><\/div><\/div><div class=\"boc_list_item  \" >\n\t\t\t\t\t<span class=\"li_icon normal \" style=\"\"><i class=\"icon icon-chevron-right\" style=\"\"><\/i><\/span>\n\t\t\t\t\t<div class=\"boc_list_item_text normal\"><\/p>\n<h4>HTS (High Temperature Storage)<\/h4>\n<p><\/div>\n\t\t\t\t   <\/div>[vc_column_text]The aim of this ageing test is to characterise the quality of Intermetallic growth. It\u2019s a long-duration and high-temperature test. 1000 hours and 125\u00b0C.<br \/>\nTechnical regulations: IEC60068 (Environmental Tests Procedures)<br \/>\n[\/vc_column_text][\/vc_column][vc_column width=&#8221;1\/2&#8243;][vc_single_image image=&#8221;25974&#8243;][\/vc_column][\/vc_row][vc_row full_width=&#8221;stretch_row&#8221; el_class=&#8221;no_text_transform&#8221; css=&#8221;.vc_custom_1494922032300{margin-top: 5% !important;margin-bottom: 10px !important;}&#8221;][vc_column width=&#8221;1\/2&#8243;]<div class=\"boc_list_item  \" >\n\t\t\t\t\t<span class=\"li_icon normal \" style=\"\"><i class=\"icon icon-chevron-right\" style=\"\"><\/i><\/span>\n\t\t\t\t\t<div class=\"boc_list_item_text normal\"><\/p>\n<h4>S.I.R. (Surface InsulationResistance)<\/h4>\n<p><\/div>\n\t\t\t\t   <\/div>[vc_column_text]This test method is used to quantify the damaging effects of manufacturing, movement processes or residues on SIR in case of humidity. The electrodes (electronically polarised during the conditioning to ease electro-chemical reactions) are placed on parallel traces on a printed circuit or on a standard assembled sheet. The samples are conditioned, and the measures are taken at a high level of humidity.<br \/>\nTest Method: IPC TM-650 2.6.3.7 (Surface Insulation Resistance)<br \/>\n[\/vc_column_text][\/vc_column][vc_column width=&#8221;1\/2&#8243;]<div class=\"boc_list_item  \" >\n\t\t\t\t\t<span class=\"li_icon normal \" style=\"\"><i class=\"icon icon-chevron-right\" style=\"\"><\/i><\/span>\n\t\t\t\t\t<div class=\"boc_list_item_text normal\"><\/p>\n<h4>ATC (Accelerated Thermal Cycling)<\/h4>\n<p><\/div>\n\t\t\t\t   <\/div>[vc_column_text]The aim of this test is to evaluate the stress to which the soldering is subjected, according to the temperature variation. The ATC involves a slow temperature variation, not more than 20\u00b0C per minute. The thermal cycle provokes a different thermal expansion \/ contraction according to the material composition, by creating mechanical stresses which include plastic deformations on the material. This provokes a stress able to speed up the life cycle of the material. For example, the thermal cycle can cause micro-fractures inside the soldering, and, after several cycles, it can cause a total breakout.<br \/>\nTechnical regulations: IEC60068 (Environmental Tests Procedures)<br \/>\n[\/vc_column_text][\/vc_column][\/vc_row][vc_row css=&#8221;.vc_custom_1496155854902{padding-top: 30px !important;}&#8221;][vc_column width=&#8221;1\/2&#8243;]<div class=\"boc_list_item  \" >\n\t\t\t\t\t<span class=\"li_icon normal \" style=\"\"><i class=\"icon icon-chevron-right\" style=\"\"><\/i><\/span>\n\t\t\t\t\t<div class=\"boc_list_item_text normal\"><\/p>\n<h4>T&amp;H Temperature and Humidity<\/h4>\n<p><\/div>\n\t\t\t\t   <\/div>[vc_column_text]The aim of this test is to evaluate the impact of chemical substances on PCBA (for example fluxes residues). This test is performed according to the JEDEC JESD22-100C Standards and by respecting the following test parameters: a duration of 240 hours, with a temperature at 85\u00b0C and 85% of humidity. The result of the functional test is considered as positive if there is no dendritic growth.<br \/>\nTechnical regulations: IEC60068 (Environmental Tests Procedures)<br \/>\n[\/vc_column_text][\/vc_column][vc_column width=&#8221;1\/2&#8243;]<div class=\"boc_list_item  \" >\n\t\t\t\t\t<span class=\"li_icon normal \" style=\"\"><i class=\"icon icon-chevron-right\" style=\"\"><\/i><\/span>\n\t\t\t\t\t<div class=\"boc_list_item_text normal\"><\/p>\n<h4>Thermal Shock<\/h4>\n<p><\/div>\n\t\t\t\t   <\/div>[vc_column_text]The thermal shocks are different from thermal cycles because of the quick temperature change. For this reason, they provoke also different failure mechanisms. During the thermal shocks, the materials are subjected to deformation phenomena. On the PCBA they cause the PCB or assembled components deformation by creating a deformation perpendicular to the sheet surface.<br \/>\nTechnical regulations: IEC60068 (Environmental Tests Procedures)<br \/>\n[\/vc_column_text][\/vc_column][\/vc_row][vc_row css=&#8221;.vc_custom_1489507990446{padding-top: 10% !important;}&#8221;][vc_column width=&#8221;1\/2&#8243;]<h2 class=\"boc_heading  al_left  \"  style=\"margin-bottom: 20px;margin-top: 0px;color: #333333;\"><span>AVAILABLE <strong>EQUIPMENT<\/strong><\/span><\/h2><div class=\"boc_divider_holder\"><div class=\"boc_divider  \"  style=\"margin-top: 20px;margin-bottom: 50px;width: 40px;height: 1px;background: #eeeeee;\"><\/div><\/div>[\/vc_column][vc_column width=&#8221;1\/2&#8243;][\/vc_column][\/vc_row][vc_row css=&#8221;.vc_custom_1500018182325{padding-top: 2% !important;}&#8221;][vc_column width=&#8221;1\/3&#8243;][vc_row_inner][vc_column_inner][vc_column_text]<\/p>\n<h3 style=\"text-align: left;\"><span style=\"color: #06b203;\">ANGELANTONI mod. CTS 157\/2T<\/span><\/h3>\n<p><span style=\"font-size: 12px; text-transform: uppercase; font-weight: 900;\">Type<\/span>: Double chamber<\/p>\n<p><span style=\"font-size: 12px; text-transform: uppercase; font-weight: 900;\">Test<\/span>:<br \/>\nThermal Cycle Chamber,<br \/>\nThermal Shock Test<\/p>\n<p><span style=\"font-size: 12px; text-transform: uppercase; font-weight: 900;\">QUANTITY<\/span>: 2<\/p>\n<p><span style=\"font-size: 12px; text-transform: uppercase; font-weight: 900;\">FEATURES: <\/span>\u00a0-60\u00b0C \/ +200\u00b0C<\/p>\n<p><span style=\"font-size: 12px; text-transform: uppercase; font-weight: 900;\">STANDARD PROFILES<\/span>: -55\u00b0C \/ +125\u00b0C<\/p>\n<p><span style=\"font-size: 12px; text-transform: uppercase; font-weight: 900;\">Ramp rate<\/span>: Transizione immediata<\/p>\n<p><span style=\"font-size: 12px; text-transform: uppercase; font-weight: 900;\">NECESSARY SIZES\u00a0 (LXHXP)<\/span>:<br \/>\n530x450x660 mm[\/vc_column_text]<div class=\"boc_spacing \" style=\"height: 20px\"><\/div>[\/vc_column_inner][\/vc_row_inner][\/vc_column][vc_column width=&#8221;1\/3&#8243;][vc_row_inner][vc_column_inner][vc_column_text]<\/p>\n<h3 style=\"text-align: left;\"><span style=\"color: #06b203;\">VOTSCH mod. VC7012 S2<\/span><\/h3>\n<p><span style=\"font-size: 12px; text-transform: uppercase; font-weight: 900;\">TYPE:<\/span>\u00a0Double chamber<\/p>\n<p><span style=\"font-size: 12px; text-transform: uppercase; font-weight: 900;\">Test<\/span>:<br \/>\nThermal Cycle Chamber,<br \/>\nThermal Shock Test<\/p>\n<p><span style=\"font-size: 12px; text-transform: uppercase; font-weight: 900;\">QUANTITY<\/span>: 1<\/p>\n<p><span style=\"font-size: 12px; text-transform: uppercase; font-weight: 900;\">FEATURES<\/span>: -80\u00b0C \/ +200\u00b0C<\/p>\n<p><span style=\"font-size: 12px; text-transform: uppercase; font-weight: 900;\">STANDARD PROFILES<\/span>: -55\u00b0C \/ +125\u00b0C<\/p>\n<p><span style=\"font-size: 12px; text-transform: uppercase; font-weight: 900;\">Ramp rate<\/span>: Transizione immediata<\/p>\n<p><span style=\"font-size: 12px; text-transform: uppercase; font-weight: 900;\">NECESSARY SIZES (LXHXP)<\/span>:<br \/>\n470x650x410 mm[\/vc_column_text]<div class=\"boc_spacing \" style=\"height: 20px\"><\/div>[\/vc_column_inner][\/vc_row_inner][\/vc_column][vc_column width=&#8221;1\/3&#8243;][vc_row_inner][vc_column_inner][vc_column_text]<\/p>\n<h3 style=\"text-align: left;\"><span style=\"color: #06b203;\">ANGELANTONI CLIMATIC SYSTEM mod. TY150C\/SP<\/span><\/h3>\n<p><span style=\"font-size: 12px; text-transform: uppercase; font-weight: 900;\">TYPE<\/span>: Single chamber<\/p>\n<p><span style=\"font-size: 12px; text-transform: uppercase; font-weight: 900;\">Test<\/span>:<br \/>\nThermal Cycle Chamber,<br \/>\nTemperature Cycling Test<\/p>\n<p><span style=\"font-size: 12px; text-transform: uppercase; font-weight: 900;\">QUANTITY<\/span>: 1<\/p>\n<p><span style=\"font-size: 12px; text-transform: uppercase; font-weight: 900;\">FEATURES<\/span>: -30\u00b0C \/ +150\u00b0C<\/p>\n<p><span style=\"font-size: 12px; text-transform: uppercase; font-weight: 900;\">STANDARD PROFILES<\/span>: 0\u00b0C \/ +100\u00b0C<\/p>\n<p><span style=\"font-size: 12px; text-transform: uppercase; font-weight: 900;\">Ramp rate<\/span>: 10\u00b0C \/ min<\/p>\n<p><span style=\"font-size: 12px; text-transform: uppercase; font-weight: 900;\">NECESSARY SIZES (LXHXP)<\/span>:<br \/>\n580x320x450 mm[\/vc_column_text]<div class=\"boc_spacing \" style=\"height: 20px\"><\/div>[\/vc_column_inner][\/vc_row_inner][\/vc_column][\/vc_row][vc_row css=&#8221;.vc_custom_1500018182325{padding-top: 2% !important;}&#8221;][vc_column width=&#8221;1\/3&#8243;][vc_row_inner][vc_column_inner][vc_column_text]<\/p>\n<h3 style=\"text-align: left;\"><span style=\"color: #06b203;\">WEISS mod. WT1-480\/70\/15<\/span><\/h3>\n<p><span style=\"font-size: 12px; text-transform: uppercase; font-weight: 900;\">TYPE<\/span>: Single chamber<\/p>\n<p><span style=\"font-size: 12px; text-transform: uppercase; font-weight: 900;\">Test<\/span>:<br \/>\nThermal Cycle Chamber,<br \/>\nTemperature Cycling Test<\/p>\n<p><span style=\"font-size: 12px; text-transform: uppercase; font-weight: 900;\">QUANTITY<\/span>: 1<\/p>\n<p><span style=\"font-size: 12px; text-transform: uppercase; font-weight: 900;\">FEATURES<\/span>: -70\u00b0C \/ +180\u00b0C<\/p>\n<p><span style=\"font-size: 12px; text-transform: uppercase; font-weight: 900;\">STANDARD PROFILES<\/span>:<br \/>\n-40\u00b0C \/ +100\u00b0C<br \/>\n-55\u00b0C \/ +125\u00b0C<\/p>\n<p><span style=\"font-size: 12px; text-transform: uppercase; font-weight: 900;\">Ramp rate<\/span>: 12\u00b0C \/ min<\/p>\n<p><span style=\"font-size: 12px; text-transform: uppercase; font-weight: 900;\">NECESSARY SIZES (LXHXP)<\/span>:<br \/>\n800x1000x600 mm[\/vc_column_text]<div class=\"boc_spacing \" style=\"height: 20px\"><\/div>[\/vc_column_inner][\/vc_row_inner][\/vc_column][vc_column width=&#8221;1\/3&#8243;][vc_row_inner][vc_column_inner][vc_column_text]<\/p>\n<h3 style=\"text-align: left;\"><span style=\"color: #06b203;\">SECASI mod. VRT50 C200 F50\/3<\/span><\/h3>\n<p><span style=\"font-size: 12px; text-transform: uppercase; font-weight: 900;\">TYPE<\/span>: Single chamber<\/p>\n<p><span style=\"font-size: 12px; text-transform: uppercase; font-weight: 900;\">Test<\/span>:<br \/>\nThermal Cycle Chamber,<br \/>\nTemperature Cycling Test<\/p>\n<p><span style=\"font-size: 12px; text-transform: uppercase; font-weight: 900;\">QUANTITY<\/span>: 2<\/p>\n<p><span style=\"font-size: 12px; text-transform: uppercase; font-weight: 900;\">FEATURES<\/span>: -30\u00b0C \/ +200\u00b0C<\/p>\n<p><span style=\"font-size: 12px; text-transform: uppercase; font-weight: 900;\">STANDARD PROFILES<\/span>:<br \/>\n0\u00b0C \/ +100\u00b0C<br \/>\n0\u00b0C \/ +125\u00b0C<\/p>\n<p><span style=\"font-size: 12px; text-transform: uppercase; font-weight: 900;\">Ramp rate<\/span>: max 8\u00b0C \/ min<\/p>\n<p><span style=\"font-size: 12px; text-transform: uppercase; font-weight: 900;\">NECESSARY SIZES (LXHXP)<\/span>:<br \/>\n340x340x435 mm[\/vc_column_text]<div class=\"boc_spacing \" style=\"height: 20px\"><\/div>[\/vc_column_inner][\/vc_row_inner][\/vc_column][vc_column width=&#8221;1\/3&#8243;][vc_row_inner][vc_column_inner][vc_column_text]<\/p>\n<h3 style=\"text-align: left;\"><span style=\"color: #06b203;\">SECASI mod. VRT50 C200 F70\/5<\/span><\/h3>\n<p><span style=\"font-size: 12px; text-transform: uppercase; font-weight: 900;\">TYPE<\/span>: Single chamber<\/p>\n<p><span style=\"font-size: 12px; text-transform: uppercase; font-weight: 900;\">Test<\/span>:<br \/>\nThermal Cycle Chamber,<br \/>\nTemperature Cycling Test<\/p>\n<p><span style=\"font-size: 12px; text-transform: uppercase; font-weight: 900;\">QUANTITY<\/span>: 1<\/p>\n<p><span style=\"font-size: 12px; text-transform: uppercase; font-weight: 900;\">FEATURES<\/span>: -70\u00b0C \/ +200\u00b0C<\/p>\n<p><span style=\"font-size: 12px; text-transform: uppercase; font-weight: 900;\">STANDARD PROFILES<\/span>:<br \/>\n-40\u00b0C \/ +65\u00b0C<br \/>\n-10\u00b0C \/ +150\u00b0C<\/p>\n<p><span style=\"font-size: 12px; text-transform: uppercase; font-weight: 900;\">Ramp rate<\/span>: 10\u00b0C \/ min<\/p>\n<p><span style=\"font-size: 12px; text-transform: uppercase; font-weight: 900;\">NECESSARY SIZES (LXHXP)<\/span>:<br \/>\n340x340x435 mm[\/vc_column_text]<div class=\"boc_spacing \" style=\"height: 20px\"><\/div>[\/vc_column_inner][\/vc_row_inner][\/vc_column][\/vc_row][vc_row css=&#8221;.vc_custom_1500018182325{padding-top: 2% !important;}&#8221;][vc_column width=&#8221;1\/3&#8243;][vc_row_inner][vc_column_inner][vc_column_text]<\/p>\n<h3 style=\"text-align: left;\"><span style=\"color: #06b203;\">MAZZALI mod. Tesys 630H<\/span><\/h3>\n<p><span style=\"font-size: 12px; text-transform: uppercase; font-weight: 900;\">TYPE<\/span>: Single chamber<\/p>\n<p><span style=\"font-size: 12px; text-transform: uppercase; font-weight: 900;\">Test<\/span>:<br \/>\nThermal Cycle Chamber,<br \/>\nTemperature Cycling Test<\/p>\n<p><span style=\"font-size: 12px; text-transform: uppercase; font-weight: 900;\">QUANTITY<\/span>: 1<\/p>\n<p><span style=\"font-size: 12px; text-transform: uppercase; font-weight: 900;\">FEATURES<\/span>: -70\u00b0C \/ +180\u00b0C<\/p>\n<p><span style=\"font-size: 12px; text-transform: uppercase; font-weight: 900;\">STANDARD PROFILES<\/span>:<br \/>\n-40\u00b0C \/ +100\u00b0C<br \/>\n-55\u00b0C \/ +125\u00b0C<\/p>\n<p><span style=\"font-size: 12px; text-transform: uppercase; font-weight: 900;\">Ramp rate<\/span>: 7\u00b0C \/ min<\/p>\n<p><span style=\"font-size: 12px; text-transform: uppercase; font-weight: 900;\">NECESSARY SIZES (LXHXP)<\/span>:<br \/>\n700x1000x700 mm[\/vc_column_text]<div class=\"boc_spacing \" style=\"height: 20px\"><\/div>[\/vc_column_inner][\/vc_row_inner][\/vc_column][vc_column width=&#8221;1\/3&#8243;][vc_row_inner][vc_column_inner][vc_column_text]<\/p>\n<h3 style=\"text-align: left;\"><span style=\"color: #06b203;\">VOTSCH mod. VC4057<\/span><\/h3>\n<p><span style=\"font-size: 12px; text-transform: uppercase; font-weight: 900;\">TYPE<\/span>: Climatic Chamber<\/p>\n<p><span style=\"font-size: 12px; text-transform: uppercase; font-weight: 900;\">Test<\/span>:<br \/>\nTemperature,<br \/>\nHumidity,<br \/>\nBias SOAK<\/p>\n<p><span style=\"font-size: 12px; text-transform: uppercase; font-weight: 900;\">QUANTITY<\/span>: 3<\/p>\n<p><span style=\"font-size: 12px; text-transform: uppercase; font-weight: 900;\">FEATURES<\/span>:<br \/>\n-40\u00b0C \/ +150\u00b0C<br \/>\n10\/98% RH<\/p>\n<p><span style=\"font-size: 12px; text-transform: uppercase; font-weight: 900;\">STANDARD PROFILES<\/span>:<br \/>\n+85\u00b0C \/ 85% RH,<br \/>\n+30\u00b0C \/ 60% RH<\/p>\n<p><span style=\"font-size: 12px; text-transform: uppercase; font-weight: 900;\">NECESSARY SIZES (LXHXP)<\/span>:<br \/>\n575x645x550 mm[\/vc_column_text]<div class=\"boc_spacing \" style=\"height: 20px\"><\/div>[\/vc_column_inner][\/vc_row_inner][\/vc_column][vc_column width=&#8221;1\/3&#8243;][vc_row_inner][vc_column_inner][vc_column_text]<\/p>\n<h3 style=\"text-align: left;\"><span style=\"color: #06b203;\">VOTSCH mod. VC7018<\/span><\/h3>\n<p><span style=\"font-size: 12px; text-transform: uppercase; font-weight: 900;\">TYPE<\/span>: Climatic Chamber<\/p>\n<p><span style=\"font-size: 12px; text-transform: uppercase; font-weight: 900;\">Test<\/span>:<br \/>\nTemperature,<br \/>\nHumidity,<br \/>\nBias SOAK<\/p>\n<p><span style=\"font-size: 12px; text-transform: uppercase; font-weight: 900;\">QUANTITY<\/span>: 1<\/p>\n<p><span style=\"font-size: 12px; text-transform: uppercase; font-weight: 900;\">FEATURES<\/span>:<br \/>\n-75\u00b0C \/ +180\u00b0C,<br \/>\n10\/98% RH<\/p>\n<p><span style=\"font-size: 12px; text-transform: uppercase; font-weight: 900;\">STANDARD PROFILES<\/span>:<br \/>\n+85\u00b0C \/ 85% RH,<br \/>\n+30\u00b0C \/ 60% RH<\/p>\n<p><span style=\"font-size: 12px; text-transform: uppercase; font-weight: 900;\">NECESSARY SIZES (LXHXP)<\/span>:<br \/>\n580x750x450 mm[\/vc_column_text]<div class=\"boc_spacing \" style=\"height: 20px\"><\/div>[\/vc_column_inner][\/vc_row_inner][\/vc_column][\/vc_row][vc_row css=&#8221;.vc_custom_1500018182325{padding-top: 2% !important;}&#8221;][vc_column width=&#8221;1\/3&#8243;][vc_row_inner][vc_column_inner][vc_column_text]<\/p>\n<h3 style=\"text-align: left;\"><span style=\"color: #06b203;\">ANGELANTONI CLIMATIC SYSTEM mod. HYGROS 600<\/span><\/h3>\n<p><span style=\"font-size: 12px; text-transform: uppercase; font-weight: 900;\">TYPE<\/span>: Climatic Chamber<\/p>\n<p><span style=\"font-size: 12px; text-transform: uppercase; font-weight: 900;\">Test<\/span>:<br \/>\nTemperature,<br \/>\nHumidity,<br \/>\nBias SOAK<\/p>\n<p><span style=\"font-size: 12px; text-transform: uppercase; font-weight: 900;\">QUANTITY<\/span>: 2<\/p>\n<p><span style=\"font-size: 12px; text-transform: uppercase; font-weight: 900;\">FEATURES<\/span>:<br \/>\n-40\u00b0C \/ +180\u00b0C,<br \/>\n10\/98% RH<\/p>\n<p><span style=\"font-size: 12px; text-transform: uppercase; font-weight: 900;\">STANDARD PROFILES<\/span>:<br \/>\n+85\u00b0C \/ 85% RH,<br \/>\n+30\u00b0C \/ 60% RH<\/p>\n<p><span style=\"font-size: 12px; text-transform: uppercase; font-weight: 900;\">DNECESSARY SIZES (LXHXP)<\/span>:<br \/>\n820x700x700 mm[\/vc_column_text]<div class=\"boc_spacing \" style=\"height: 20px\"><\/div>[\/vc_column_inner][\/vc_row_inner][\/vc_column][vc_column width=&#8221;1\/3&#8243;][vc_row_inner][vc_column_inner][vc_column_text]<\/p>\n<h3 style=\"text-align: left;\"><span style=\"color: #06b203;\">A.C.S. mod. CHALLANGE 250-TC<\/span><\/h3>\n<p><span style=\"font-size: 12px; text-transform: uppercase; font-weight: 900;\">TYPE<\/span>: Single chamber<\/p>\n<p><span style=\"font-size: 12px; text-transform: uppercase; font-weight: 900;\">Test<\/span>:<br \/>\nThermal Cycle Chamber,<br \/>\nTemperature Cycling Test<\/p>\n<p><span style=\"font-size: 12px; text-transform: uppercase; font-weight: 900;\">QUANTITY<\/span>: 2<\/p>\n<p><span style=\"font-size: 12px; text-transform: uppercase; font-weight: 900;\">FEATURES<\/span>: -55\u00b0C \/ +180\u00b0C<\/p>\n<p><span style=\"font-size: 12px; text-transform: uppercase; font-weight: 900;\">STANDARD PROFILES<\/span>:<br \/>\n-40\u00b0C \/ +100\u00b0C<br \/>\n-55\u00b0C \/ +125\u00b0C<\/p>\n<p><span style=\"font-size: 12px; text-transform: uppercase; font-weight: 900;\">Ramp rate<\/span>: 3\u00b0C \/ min<\/p>\n<p><span style=\"font-size: 12px; text-transform: uppercase; font-weight: 900;\">NECESSARY SIZES (LXHXP)<\/span>:<br \/>\n520x700x520 mm[\/vc_column_text]<div class=\"boc_spacing \" style=\"height: 20px\"><\/div>[\/vc_column_inner][\/vc_row_inner][\/vc_column][vc_column width=&#8221;1\/3&#8243;][vc_row_inner][vc_column_inner][vc_column_text]<\/p>\n<h3 style=\"text-align: left;\"><span style=\"color: #06b203;\">MAZZALI mod. Thermair 700<\/span><\/h3>\n<p><span style=\"font-size: 12px; text-transform: uppercase; font-weight: 900;\">TYPE<\/span>: Thermal Oven<\/p>\n<p><span style=\"font-size: 12px; text-transform: uppercase; font-weight: 900;\">Test<\/span>:<br \/>\nCure &amp; Bake<\/p>\n<p><span style=\"font-size: 12px; text-transform: uppercase; font-weight: 900;\">QUANTITY<\/span>: 1<\/p>\n<p><span style=\"font-size: 12px; text-transform: uppercase; font-weight: 900;\">FEATURES<\/span>: +150\u00b0C<\/p>\n<p><span style=\"font-size: 12px; text-transform: uppercase; font-weight: 900;\">STANDARD PROFILES<\/span>: +40\u00b0C \/ +250\u00b0C<\/p>\n<p><span style=\"font-size: 12px; text-transform: uppercase; font-weight: 900;\">NECESSARY SIZES (LXHXP)<\/span>:<br \/>\n430x430x480 mm[\/vc_column_text]<div class=\"boc_spacing \" style=\"height: 20px\"><\/div>[\/vc_column_inner][\/vc_row_inner][\/vc_column][\/vc_row][vc_row css=&#8221;.vc_custom_1500018182325{padding-top: 2% !important;}&#8221;][vc_column width=&#8221;1\/3&#8243;][vc_row_inner][vc_column_inner][vc_column_text]<\/p>\n<h3 style=\"text-align: left;\"><span style=\"color: #06b203;\">BIOBLOCK<\/span><\/h3>\n<p><span style=\"font-size: 12px; text-transform: uppercase; font-weight: 900;\">TYPE<\/span>: Thermal Oven<\/p>\n<p><span style=\"font-size: 12px; text-transform: uppercase; font-weight: 900;\">Test<\/span>: Cure &amp; Bake<\/p>\n<p><span style=\"font-size: 12px; text-transform: uppercase; font-weight: 900;\">QUANTITY<\/span>: 1<\/p>\n<p><span style=\"font-size: 12px; text-transform: uppercase; font-weight: 900;\">FEATURES<\/span>: +125\u00b0C<\/p>\n<p><span style=\"font-size: 12px; text-transform: uppercase; font-weight: 900;\">STANDARD PROFILES<\/span>: +40\u00b0C \/ +200\u00b0C<\/p>\n<p><span style=\"font-size: 12px; text-transform: uppercase; font-weight: 900;\">NECESSARY SIZES(LXHXP)<\/span>:<br \/>\n430x450x460 mm[\/vc_column_text]<div class=\"boc_spacing \" style=\"height: 20px\"><\/div>[\/vc_column_inner][\/vc_row_inner][\/vc_column][vc_column width=&#8221;1\/3&#8243;][\/vc_column][vc_column width=&#8221;1\/3&#8243;][\/vc_column][\/vc_row][vc_row full_width=&#8221;stretch_row&#8221; enable_overlay=&#8221;off&#8221; el_class=&#8221;white_text&#8221; css=&#8221;.vc_custom_1489679206352{margin-top: 10% !important;margin-bottom: 0px !important;padding-top: 24px !important;padding-bottom: 20px !important;background-color: #40981e !important;}&#8221;][vc_column]<div class=\"text_box no_text_transform body_font box_no_bgr \"><div class=\"text_box_content with_button\"><h2>Contact us to request a quote<\/h2>\n\t\t\t\t\t<p>Our experts will be available to offer a solution for your needs.<\/p>\n\t\t\t\t<\/div><div class=\"btn_holder\"><a\thref=\"https:\/\/www.gestlabs.it\/en\/ask-for-a-quote\/\" \n\t\t\t\t\tclass=\"button  btn_medium_stretched btn_white btn_circled btn_outline icon_pos_after \"  target='_self'><span>REQUEST A QUOTE<\/span> <i class='icon icon icon-angle-right2'><\/i> <\/a><\/div><\/div>[\/vc_column][\/vc_row]<\/p>\n","protected":false},"excerpt":{"rendered":"<p>[vc_row full_width=&#8221;stretch_row&#8221; bg_type=&#8221;image&#8221; parallax_style=&#8221;vcpb-vz-jquery&#8221; bg_image_new=&#8221;24939&#8243; bg_image_repeat=&#8221;no-repeat&#8221; parallax_sense=&#8221;40&#8243; disable_on_mobile_img_parallax=&#8221;off&#8221; parallax_content=&#8221;off&#8221; fadeout_row=&#8221;off&#8221; enable_overlay=&#8221;enable_overlay_value&#8221; overlay_color=&#8221;rgba(0,0,0,0.34)&#8221; css=&#8221;.vc_custom_1499264580063{margin-bottom: 0px !important;padding-top: 240px !important;padding-bottom: 160px !important;}&#8221;][vc_column][\/vc_column][\/vc_row][vc_row css=&#8221;.vc_custom_1489507990446{padding-top: 10% !important;}&#8221;][vc_column width=&#8221;1\/2&#8243;][vc_column_text]The aim of this ageing test is to characterise the quality of Intermetallic growth. It\u2019s a long-duration and high-temperature test. 1000 hours and 125\u00b0C. Technical regulations: IEC60068 (Environmental Tests Procedures) [\/vc_column_text][\/vc_column][vc_column width=&#8221;1\/2&#8243;][vc_single_image image=&#8221;25974&#8243;][\/vc_column][\/vc_row][vc_row full_width=&#8221;stretch_row&#8221; el_class=&#8221;no_text_transform&#8221; css=&#8221;.vc_custom_1494922032300{margin-top: 5% !important;margin-bottom:<\/p>\n<div class=\"h10\"><\/div>\n<p><a class=\"more-link1\" href=\"https:\/\/www.gestlabs.it\/en\/environmental-testing-temperature-humidity\/\">Read more<\/a><\/p>\n","protected":false},"author":4,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"open","ping_status":"open","template":"","meta":{"_links_to":"","_links_to_target":""},"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v17.8 (Yoast SEO v17.8) - https:\/\/yoast.com\/wordpress\/plugins\/seo\/ -->\n<title>Test ambientali e di affidabilit\u00e0 | GESTLABS<\/title>\n<meta name=\"description\" content=\"I nostri laboratori possono eseguire una lunga serie di test per valutare e validare nuovi processi e tecnologie.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.gestlabs.it\/en\/environmental-testing-temperature-humidity\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"ENVIRONMENTAL AND RELIABILITY TEST\" \/>\n<meta property=\"og:description\" content=\"The aim of this ageing test is to characterise the quality of Intermetallic growth. It\u2019s a long-duration and high-temperature test. 1000 hours and 125\u00b0C.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.gestlabs.it\/en\/environmental-testing-temperature-humidity\/\" \/>\n<meta property=\"og:site_name\" content=\"GESTLABS\" \/>\n<meta property=\"article:modified_time\" content=\"2021-08-05T10:54:13+00:00\" \/>\n<meta name=\"twitter:card\" content=\"summary\" \/>\n<meta name=\"twitter:label1\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data1\" content=\"5 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebSite\",\"@id\":\"https:\/\/www.gestlabs.it\/#website\",\"url\":\"https:\/\/www.gestlabs.it\/\",\"name\":\"GESTLABS\",\"description\":\"Laboratori GESTLABS\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/www.gestlabs.it\/?s={search_term_string}\"},\"query-input\":\"required name=search_term_string\"}],\"inLanguage\":\"en-US\"},{\"@type\":\"WebPage\",\"@id\":\"https:\/\/www.gestlabs.it\/en\/environmental-testing-temperature-humidity\/#webpage\",\"url\":\"https:\/\/www.gestlabs.it\/en\/environmental-testing-temperature-humidity\/\",\"name\":\"Test ambientali e di affidabilit\\u00e0 | GESTLABS\",\"isPartOf\":{\"@id\":\"https:\/\/www.gestlabs.it\/#website\"},\"datePublished\":\"2017-05-16T13:14:22+00:00\",\"dateModified\":\"2021-08-05T10:54:13+00:00\",\"description\":\"I nostri laboratori possono eseguire una lunga serie di test per valutare e validare nuovi processi e tecnologie.\",\"breadcrumb\":{\"@id\":\"https:\/\/www.gestlabs.it\/en\/environmental-testing-temperature-humidity\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/www.gestlabs.it\/en\/environmental-testing-temperature-humidity\/\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/www.gestlabs.it\/en\/environmental-testing-temperature-humidity\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/www.gestlabs.it\/en\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"ENVIRONMENTAL AND RELIABILITY TEST\"}]}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"Test ambientali e di affidabilit\u00e0 | GESTLABS","description":"I nostri laboratori possono eseguire una lunga serie di test per valutare e validare nuovi processi e tecnologie.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.gestlabs.it\/en\/environmental-testing-temperature-humidity\/","og_locale":"en_US","og_type":"article","og_title":"ENVIRONMENTAL AND RELIABILITY TEST","og_description":"The aim of this ageing test is to characterise the quality of Intermetallic growth. It\u2019s a long-duration and high-temperature test. 1000 hours and 125\u00b0C.","og_url":"https:\/\/www.gestlabs.it\/en\/environmental-testing-temperature-humidity\/","og_site_name":"GESTLABS","article_modified_time":"2021-08-05T10:54:13+00:00","twitter_card":"summary","twitter_misc":{"Est. reading time":"5 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebSite","@id":"https:\/\/www.gestlabs.it\/#website","url":"https:\/\/www.gestlabs.it\/","name":"GESTLABS","description":"Laboratori GESTLABS","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.gestlabs.it\/?s={search_term_string}"},"query-input":"required name=search_term_string"}],"inLanguage":"en-US"},{"@type":"WebPage","@id":"https:\/\/www.gestlabs.it\/en\/environmental-testing-temperature-humidity\/#webpage","url":"https:\/\/www.gestlabs.it\/en\/environmental-testing-temperature-humidity\/","name":"Test ambientali e di affidabilit\u00e0 | GESTLABS","isPartOf":{"@id":"https:\/\/www.gestlabs.it\/#website"},"datePublished":"2017-05-16T13:14:22+00:00","dateModified":"2021-08-05T10:54:13+00:00","description":"I nostri laboratori possono eseguire una lunga serie di test per valutare e validare nuovi processi e tecnologie.","breadcrumb":{"@id":"https:\/\/www.gestlabs.it\/en\/environmental-testing-temperature-humidity\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.gestlabs.it\/en\/environmental-testing-temperature-humidity\/"]}]},{"@type":"BreadcrumbList","@id":"https:\/\/www.gestlabs.it\/en\/environmental-testing-temperature-humidity\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.gestlabs.it\/en\/"},{"@type":"ListItem","position":2,"name":"ENVIRONMENTAL AND RELIABILITY TEST"}]}]}},"_links":{"self":[{"href":"https:\/\/www.gestlabs.it\/en\/wp-json\/wp\/v2\/pages\/25976"}],"collection":[{"href":"https:\/\/www.gestlabs.it\/en\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.gestlabs.it\/en\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.gestlabs.it\/en\/wp-json\/wp\/v2\/users\/4"}],"replies":[{"embeddable":true,"href":"https:\/\/www.gestlabs.it\/en\/wp-json\/wp\/v2\/comments?post=25976"}],"version-history":[{"count":11,"href":"https:\/\/www.gestlabs.it\/en\/wp-json\/wp\/v2\/pages\/25976\/revisions"}],"predecessor-version":[{"id":26609,"href":"https:\/\/www.gestlabs.it\/en\/wp-json\/wp\/v2\/pages\/25976\/revisions\/26609"}],"wp:attachment":[{"href":"https:\/\/www.gestlabs.it\/en\/wp-json\/wp\/v2\/media?parent=25976"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}